Single Zone microprocessor based greenhouse control system for ventilation, heating and air circulation needs.
Programing Switches LED status lights for:
|
Run Mode |
Dehumidification |
|
Vent A |
Set mode/clock |
|
Vent B |
Calibrate |
|
Heating |
Set Up Vent |
The Ventmate Plus provides for control of 2 sets of vents, 2 stages ofheating, one stage of dehumification and one stage HAF air circulation.
Standard Sensors provided air air temperature sensor and photocell sensor. Humidity sensor is optional and is required for dehumidification functions.
Temperature Accuracy Temperature : +/- 1 deg. F Optional Humidity Sensor Humidity: +/- 2% RH Digital readout .7" LCD, 6 segment, high visibility Programming Front panel toggle switches Output Switches Center Off, Automatic and Manual Lighted Status Indicators High Intensity LED Maximum Ventilation Stages 8 stages for each set, 2 set. Number of Heating Stages 2 Stages Air Circulation Stages 1 Stage, user adjustable Time delay User selectable: 2, 10, 30 sec. or 1.5, 2, 5 min. Temperature Separation User selectable: 1 to 8 deg. F Temperature Differential User selectable: 1 to 8 deg. F Fahrenheit or Centigrade User selectable Temperature Setpoints Separate Cooling, Heating and Ventilation Available Modes Day and Night and DIF capable Enclosure Weatherproof, clear cover, lockable Voltage 24 VAC, low voltage Physical Size 8.5" W X 10.5" H X 5.5" D
COMPARISON SHEET
VENTMATE PLUS VERSES
WADSWORTH STEP 50 AND 500 CONTROLS.
|
Features |
|
|
|
|
Number of active cooling stages |
|
|
|
|
Maximum Number fo Stages Per Vent |
|
||
|
Number of Heating Stages |
|
|
|
|
Air Circulation Stage |
|
|
|
|
Manual Override Switches |
|
|
|
|
Digital Display |
|
|
|
|
Front Panel Display |
|
|
|
|
Digital Programing |
|
|
|
|
Computer Based Control |
|
|
|
|
All Low Voltage, 24 VAC |
|
|
|
|
DIF Capability |
|
|
|
|
Separate Day and Night Vent Settings |
|
|
|
|
Separte Day and Night Heating Settings |
|
|
|
|
Sealed locakabe Enclosure |
|
|
|
|
Full Clear Lexam Cover |
|
|
|
|
Humdity Sensor Available |
|
|
|
|
True Dehumidification |
|
|
|
|
Adjustable Air Circulation Stage |
|
|
|
|
Internal 24 hour time clock and photo cell |
|
|
|
|
Displays Hight and Low Temperatures |
|
|
|
Ventmate Plus
Computer Based Greenhouse Control System
Passive Cooling
Side Vents
Roof Vents
Roll Up CurtainsBy using the stadnard outputs in the Ventmate Plus, any morotized vent system or curtain roll up system can be opend in up to ieght stages without the need for any external limit switches. Changing position openings can be done in seconds from the front panel. All passive outputs feature adjustabe time delays, temperature spans and differentials. Up to two series or sets of vents can be controlled.
Air Circulation
Hortizontal Air Flow Fans / Fan JetsThe Ventmate Plus features air circulation capabilities that can operate any equipment to turn on or off in relation to a vent stage.
Active Heating
Gas fired Heaters
Hot water zone Valves
The Ventmate Plus system will operate any active heating equipment in maintained stages of operation. Two separate temperature setting can be enters for all equipment. Day and Night Modes are standard. All active outputs feature adjustable time delays, temperature spans and differentials.
Special Feature
RH - dehumidification
The inclusion of this special feature sets the Ventmate Plus far apart from standard greenhouse control systems. The addition of a true digital humidity sensor allows the grower to monitor the humidity level and dehumidify the greenhouse if needed. The Growmate Plus will also recall the highest and lowest temperature and humdity level for the previous 24 hour period.
AGROPONIC INDUSTRIES LTD.
908 RANCHVIEW CRES. NW., CALGARY, ALBERTA, CANADA, T3G1P9
ph (403)241-8234, fax (403)241-8234
Email: agropon@agroponic.com, ULR: www.agroponic.com